Product Details:
Payment & Shipping Terms:
|
External Dimension: | W×D×H 650x650x1150mm | Material: | Galvanized Steel |
---|---|---|---|
Cooling System: | DC48V Heat Exchanger And DC48V Fans | Coating: | Anti-corrosion Outdoor Powder Coating |
Cabinet Lock: | Anti-theft Three Point Lock | Cable Entry: | At Cabinet Bottom |
Protection: | High Stability, Anti-UV Radiation, Anti-corrosion, Integrated Top Cover, Good Seal, Water Proof, IP55 | Grounding Protection: | Copper Bar |
Installation Method: | Wallmounted | Cabinet Layout: | One Compartment, For Installing 19” Equipment And Battery |
Protection Level: | IP55 | Heat Insulation: | PEF |
Structure: | Sandwich Structure Double Wall, With Insulation | Telecom Power System: | 90A,4800W |
Good Seal Waterproof Sandwich Structure Outdoor Wall Mounted Cabinet With Telecom Power System And Battery
1. Application
The ET6565115-W Wall Mounted Outdoor Telecom Cabinet is widely used in wireless communication base station, such as 3G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.
Suitable for outdoor environment, such as roadside, park, remote mountain area, building roof. The cabinet can install base station equipment, power equipment, battery, temperature control equipment, transmission equipment and other matching equipment or reserve space and heat exchange capacity for the above equipments, can provide reliable mechanical and environmental protection for the normal operation of internal equipment.
2. Specifications
(1)Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension | External Dimension: W×D×H 650x650x1150mm Internal Dimension: W×D×H 550x550x950mm |
Layout | One compartment | |
Equipment Installation Method | 19” standard rack and battery shelf | |
Door | With one front door, and anti-theft three point lock for outdoor cabinet (support padlock) | |
Material |
1.Galvanized steel; 2.Double wall with 40mm PEF heat insulation between two walls. |
|
Structure | Welded | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | 800W DC48V heat exchanger and DC48V fans |
Lightning Protection | Grade B Lightning Protection | Nominal: 60KA; Max: 100KA |
Lighting | LED lamp | 48V LED lamp |
Temperature | Temperature | Working Temperature: -20°C ~ 55°C |
Storage Temperature: -40°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1124 × (1±5%)W/m2 |
(2)Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Wall Mounted Cabinet | 1 | Set |
External Dimension:W×D×H 650x650x1150mm Internal Dimension:W×D×H 550x550x950mm (2) One compartment: the upper compartment is used for installing equipment, the lower compartment is used for installing battery (3) With one front door and anti-theft three point lock for outdoor cabinet (support padlock) (4) Material: Galvanized steel; double wall, 1.5mm thick outer plate, 0.8mm thick inner plate. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF. |
2 | Heat Exchanger | 1 | Set |
Cooling capacity: 800W, Power supply: DC48V, Model: HE06-80SEH/01 |
3 | Telecom Power System | 1 | Set | GPE4890B, 90A, DC48V,1U, 4800W including: Power distribution frame x 1; 30A rectifier module x 3; Monitoring module x 1 |
4 | Fan | 2 | PC | DC48V, installed on the top, start at 35°C |
5 | Door Sensor | 1 | PC | Used for door open alarm |
6 | LED Sensor | 1 | PC | Used for controlling LED lamp on /off |
7 | LED lamp | 1 | PC | DC48V |
8 | Breaker | 1 | Set | AC input C32A 2P*1 |
9 | Lead Acid Battery | 4 | PC | Model: SP12-26, 12V 26Ah |
10 | Package | 1 | Set | Wooden Case |
3. Structure
The cabinet is made of hot dip galvanized steel, double walls structure. There are heat insulation between the two walls. It is easy for installation and with perfect sealing performance.
Equipment Compartment: The ET6565115-W cabinet is used for installing telecom equipments and battery. The cabinet is a double-wall cabinet, with heat insulation between the two walls. It uses 4 fans for cooling. It is sunproof and waterproof.
Door and Door Lock: The cabinet door uses embedded structure. The door opening angle is larger than 110° and the door limit device can limit the opening angle. The lock is theftproof three point lock, supports padlock.
Cabinet External Size : 650x650x1150mm (W×D×H),
Cabinet Internal Size : 550x550x950mm (W×D×H)
4. Features
4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
4.2 The cabinet use heat exchanger and fans for cooling.
4.3 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There’re entrance holes individually for power cable, signal cable and optical cable.
4.4 All the cables used in the cabinet are made from flame retardant materials.
4.5 Perfect protection
● Integrated top cover, good seal, water proof
● Protection Grade: IP55
● High stability, anti-UV radiation
● Anti-corrosion
4.6 Heat Insulation
● Sandwich structure insulates the outer heat conduct, keeping temperature inside cabinet without abrupt change, anti-condensation, reducing heat management energy consumption.
● High performance PEF insulation material
5. Technical Specs
5.1 Applicable environment conditions:
Environment temperature: -40°C ~ + 60°C
Environment humidity (RH): ≤95% (at + 40°C)
Air pressure: 70kPa ~ 106kPa
5.2 Material: hot dip galvanized steel
5.3 Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
5.4 Cabinet load bearing: ≥600kg
5.5 Ingress protection: IP55
5.6 Flame retardance: comply with GB5169.7 test A
5.7 Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2X104M/500V(DC).
5.8 Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V (DC) /1min.
5.9 Mechanical strength: each surface can bear upright pressure>980N; after the door is open, its outer end can bear upright pressure >200N.
6. Description
6.1 Cable Entrance
All outside cables use bottom entrance method.
6.2 Grounding Protection
(1) The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
(2) The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
6.3 Theft Proof Design
Door lock theft proof design
(1) Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
(2) Three point lock
6.4 Connection and Fastening
(1)Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2)Door hinges use inner hinge mode.
6.5 Appearance and Surface Treatment
Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.
6.6 LED lamp, LED lamp sensor, door sensor and fan are installed at the top of the cabinet.
6.7 Ventilation
Air Outlet:
Air Inlet:
6.8 Installation Method-Wall Mounted Methods
7. Packing
The cabinet packing is wooden case in compliance with GB3873-83, damp proof and shock proof. The outside of the packing is painted with damp proof sign, shock proof sign, direction sign, etc.