Product Details:
Payment & Shipping Terms:
|
DDTE053 Three Compartments Outdoor Telecom Cabinet
Item |
Type |
Technical Parameter |
Structure |
Dimension |
External Dimension: H*W*D 2000*2400*800 Internal Dimension: H*W*D 1700*2350*750 |
Layout |
3 compartments |
|
Equipment Installation Method |
19” rack |
|
Door |
With three front doors, and special lock for outdoor cabinet (support padlock) |
|
Material |
Galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate |
|
Heat Insulation |
There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF. |
|
Structure |
Welded or Assembled |
|
Ingress Protection |
IP55 |
|
Temperature Control |
Cooling |
AC220V air conditioner and DC48V fans |
Lightning Proof |
Grade B lightning proof |
Nominal: 60KA, Max.: 100KA |
Lighting |
LED lamp |
48V LED lamps (immovable), with protective circuit breaker |
Temperature |
Temperature |
Working Temperature: -40°C ~ +55°C |
|
|
Storage Temperature: -50°C ~ + 70°C |
|
|
Transport Temperature: -50°C ~ +70°C |
Humidity |
Relative Humidity |
5% ~ 100% |
Pressure |
Air Pressure |
62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity |
Solar Radiation Intensity |
1120 ×(1±5%)W/m2 |
4. Accessories List
No. |
Item |
Quantity |
Unit |
Specs |
1 |
Outdoor Telecom Cabinet |
1 |
Set |
(1) External Dimension: H*W*D 2000*2400*800 Internal Dimension: H*W*D 1700*2350*750; (2) 3 compartments: the left part is battery compartment, the middle and the right parts are equipment compartments; (3) With three front door, and special lock for outdoor cabinet (support padlock) ; (4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate; |
2 |
Air Conditioner |
3 |
Set |
(1) Cooling capacity: 1.2KW, AC220V, 50HZ; Model:TC06-120JFH/01, Quantity:2 sets (2) Cooling capacity: 500W, AC220V, 50HZ; Model:TC06-050JFH/01 Quantity:1 set |
3 |
Auxiliary Direct Ventilation Fans |
5 |
PC |
12038 DC48V |
4 |
Environment Monitoring Unit |
1 |
Set |
2U, Model: SM2200 |
5 |
Water Sensor |
1 |
PC |
|
6 |
Smoke Sensor |
1 |
PC |
|
7 |
Temperature and Humidity Sensor |
2 |
PC |
|
8 |
Door Sensor |
6 |
PC |
One for controlling LED lamp, the other for open door alarm |
9 |
LED Lamp |
3 |
PC |
DC48V |
10 |
Embedded Telecom Power System (UPS/Rectifier) |
1 |
Set |
3U,DC48V, 120A, 57600W; |
11 |
Power Distribution Unit |
1 |
Set |
Grade B Lightning Proof AC Input: 63A/2P *1; AC Output: 16A/1P*4; DC Output: 16A/1P*4 |
12 |
DDF |
1 |
Set |
|
13 |
ODF |
1 |
Set |
24 cores, wiring terminal box*1 |
14 |
Package |
1 |
Set |
Wooden Case |
5. Cabinet Dimension Diagram