TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

 

We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom power system.

Sales & Support
Request A Quote - Email
Select Language
English
Portuguese
中文
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsTelecom Power System (Rack Mount UPS)

GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC

China GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC supplier

Large Image :  GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC

Product Details:

Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001:2008
Model Number: GPE48150A

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Packaging Details: Wooden Case
Delivery Time: 10 Days
Payment Terms: T/T,L/C
Supply Ability: 80000 Sets
Contact Now
Detailed Product Description

Power System of High Performance and High Reliability

GPE48150A Embedded Power System

Input:90~290Vac; Output: -42~-58Vdc;

The GPE48150A embedded power system consists of the power distribution frame, monitoring module and rectifier module. The whole system is of high reliability and performance, and can be operated through PC software.

 
Application
 
■   Small scale program controlled exchangers
■   Access network
■   Transmission equipment
■   Mobile communication
■   Satellite communication ground station
■   Microwave communication
 
Main features
 
Adoption of active power factor compensation technology with factor >0.98
Wide operating range of AC input voltage: 90~290Vac
Operating temperature range: -25°C~+55°C
Zero current/voltage switching tech with high efficiency ≥91%
Lifecycle of battery prolonged by perfect battery management,  including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
Hot-swappable
Input over/under voltage protection
Output over voltage protection
Output over current protection
Output short circuit protection
Auto current sharing, parallel output
Embedded mounting
 
1. General Introduction
 
1.1 GPE48150A System Configuration
 
GPE48150A consists of power distribution unit, rectifier module (from 1 set, up to 3 sets) and 1 monitoring module. The configuration is optional, as following table: 
 

Configuration

Rectifier Module

Monitoring Module

Power Distribution

Remark

Standard

GPR4830A

GPM48DI (With Ethernet Port)

AC power distribution: single phase 3 wire input, main power 2 phase AC MCB (50A);

DC power distribution: battery fuse 80A×1;

LVLD: 40A×3  

LVBD: 10A×1 

For details, please refer to the specifications of modules.

Optional 1

GPR4810A

GPM48D  (Without Ethernet Port)

Optional 2

GPR4815A

Optional 3

GPR4820A

 
1.2 GPE48150A Operating Principle
 
AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. LOAD1-, LOAD2-, LOAD3-, LOAD4- are connected with two load down contactor KM1, KM2. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.
 
Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the monitoring module will control the contactor KM1 to cut off LOAD3 and LOAD4 and retains power to LOAD1 and LOAD2 . If battery voltage drops to -43.0V±0.5V (adjustable), the monitoring module will control the contactor KM2 to cut off output of LOAD1 and LOAD2, then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.
 

1.3 GPE48150A Properties

Input

Parameter

Min.

Typical

Max.

Unit

Remark

Input voltage range

90

220

285

Vac

 

Input frequency

45

50

65

Hz

 

Input current

 

 

50

A

                                 

Power factor

0.98

 

 

 

 

 

Output

Parameter

Min.

Typical 

Max.

Unit

Remark

Output voltage range

42

53.5

58

Vdc

 

Output current range

0

 

150

A

176~285VAC

0

 

75

A

90~175VAC

Ripple (Vp-p)

 

 

200

mv

At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz.

Output efficiency

90

92

 

%

220Vac input

83

85

 

%

110Vac input

Regulation

 

 

±1

%

 

Load regulation

 

 

±1

%

 

Line regulation

 

 

±1

%

 

 

Insulation rating

Parameter

Min.

Typical

Max.

Unit

Remark

Input-chassis

 

2121

 

Vdc

 

Input - output 

 

2121

 

Vdc

 

Output - chassis

 

750

 

Vdc

 

Insulation resistance

At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

 

Ambient requirements

Parameters

Min.

Typical

Max.

Unit

Remark

Operating temp

-25

 

55

°C

When ≥55°C, derating output

Storage tempStorage temperature

-40

 

80

°C

 

Relative humidity

10

 

90

%

no condensing

Atmospheric pressure

70

 

106

KPa

 

Altitude

0

 

3000

m

 

Cooling method

Forced cooling with fan

 

Mechanical specifications

Dimensions (mm)

482.6mm×255mm×130.5mm

Weight (kg)

≤11kg (Inclusive of module)

 ≤5.175kg (Frame + Distribution, exclusive of module)

GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC

2. Installation Instruction
 
2.1 Installation Dimension
 
GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC
2.2 GPE48150A Installation
 
GPE48150A is embedded power system. First insert GPE48150A to the specified location inside the cabinet till the system is well fixed. Keep the 4 fixing holes on the bracket in line with those on the cabinet and then screw up 4 pcs M4 cross rounded head screws (including spring washer and flat washer). Finally complete the installation after tightening the screw.
Note: The cabinet shall be provided by the user.
 
 
3. Electrical Connection
 
3.1 Electrical Connection Instruction
 
Chassis connects with external electric through system interface board. As shown in figure below: 
 
GPE48150A,Telecom Power System/Base Station Rectifier,Input:90~290VAC,Output: -42~-58VDC
Wiring Terminal Instruction:

                                     (1) LOAD(+): system load anode; LOAD(-): system load cathode;

        (2) BATT(+) and BATT(-) are battery interface

3.2 Process of Electric Connections

Electric connection between main cabinet and external equipments includes: connection of AC input, connection of DC output and battery, connection of communication cables, connection of GND cables. The main requirements of electrical connection are safety and reliability. The following are detailed description.
(1)AC Input Cable Connection
The connectors for AC input cable are 3 PIN terminal on the front panel of system. The AC cable can be directly inserted.
(2)Connection of DC Load Cables
The load connection connectors of power system are LOAD1, LOAD2, LOAD3, LOAD4, locating on the front panel of the system. The connection cable can be directly inserted into connector.
a. The specifications and model of load cables shall be according to the engineering design requirements.
b. Connect one end of positive connection cable to “LOAD+” at the front of system;
c. Connect one end of negative connection cable to “LOAD-” at the front of system;
(3)Connection of DC Battery Cables
Connection terminal of system and battery is 2PIN connector, indicated as BATT, used for connecting batteries. The connection cable can be directly inserted into the connector. The detailed process of battery connection is as following: 
a. Prepare positive connection cables and negative connection cables(including terminals and polarity identifications ready).
b. Fasten up the battery connection cable
c. Connect one end of positive connection cable to BATT “+” at the front of system;
d. Connect one end of negative connection cable to BATT “-” at the front of system;
(4)Recommended Cable Specifications
 

Item

   Sign

AWG/ Min. Section

(#/mm2)

AWG / Max. Section

(#/mm2)

Temp Rating

(°C)

Withstand Voltage

(V)

Output load wire

Load1, Load1-,

Load2, Load2-

12#/4

10#/5.5

105

600

Output load wire

Load3, Load3-

Load4, Load4-

6#/10

4#/16

105

600

Input GND wire

PEin

9#/6

6#/10

105

600

Mains neutral wire

Nin

6#/10

4#/16

105

600

Mains live wire

Lin

6#/10

4#/16

105

600

Battery +

(BATT +)

4#/16

4#/16

105

600

Battery -

(BATT -)

4#/16

4#/16

105

600

 
(5)Connection of GND Cables
PE connection: Connect the chassis GND point of system main cabinet and external earth with cable of 12mm2 above.
(6)Connection of Communication Cables
Communication interface RS485 of GPE48150A locate at the front panel of the system. RS485 is commnication port, with function of communication with the host. 
RS-485 communication mode:
a. Connect one end of communication cable to RS485 at front panel of GPE48150A.
b. Connect the other end of communication cable to RS485 on host. RS485 A, B line of GPE48150A respectively corresponding with RS485 A, B line of host.
 
4. Instruction of Monitoring Module GPM48DI 
 
4.1 Monitoring Module Function
 
 

Function

Remark

Remote monitoring on monitoring module by the host

The host can conduct enquiries, settings and control upon the monitoring and realize the remote message, remote sense and remote control.

Rectifier management by monitoring module

To send controlling orders or to get data from the rectifier module via RS485 communication.

Battery management

To manage the low voltage, power down, equalizing/float charge, temperature compensation of the battery.

System output management by monitoring module

To inspect and control the system

LED indicator

Signal indication

6 dry contacts output

Dry contact setting

COM port signal

 

LCD display 

to conduct setting and modification on the menu

For details, please refer to specifications of “GPM48DI”.

 
4.2 Monitoring Module Installation
 
Handles on panel of monitoring module are equipped. When inserting monitoring module into the main cabinet, the operator shall clutch the handle with one hand while holding it with the other hand. Slowly push the module into its slot until the connection terminal on back of the module are inserted into corresponding socket of system bar in the main cabinet. Finally, finish the installation by firmly fixing the screw on the panel to the main cabinet. When removing module from the main cabinet, first screw off the screw on panel, then slowly remove the module from its slot while clutching the handle. 
 
5. GPR4830A Rectifier Module Instruction
 
5.1 Instruction of Rectifier Parameters
 
 

Item

Unit

Min.

Typical

Max.

Testing conditions

AC Input Voltage

Vac

90

220

280

 

AC input voltage frequency

Hz

45

50

65

Rated load

Input power factor

 

0.99

 

 

Rated voltage/rated load

Output voltage range

Vdc

42

54

58

 

Output current

A

0

30

 

176~290V AC input

Output voltage regulation

 

 

 

±1%

 

Peak-peak value Vp-p

mV

 

 

200

Tested with each of 0.1uF ceramic capacitor and 10uF electrolytic capacitor with 20MHz band width.

Output power

W

0

1600

 

176~280V input

W

0

600

 

90~175V input

Output efficiency

%

91

 

 

220V AC input 

%

83

 

 

110V AC input

Input over voltage protection

Vdc

285

305

 

With 15A testing, automatically recoverable

Input over voltage protection recovery point

Vdc

280

 

 

Return difference not less than 5V

Input under voltage protection

Vdc

 

 

85

With 4A testing, automatically recoverable

Input under voltage protection recovery point

Vdc

 

 

90

Return difference not less than 5V

Output over voltage protection point

V

58.5

59

61.5

 

locked up

 

Output current limiting protection

A

32

33

34

Automatically recoverable

Short circuit protection 

A

long-term short circuit is available; Hiccup when short circuit detected, automatically recoverable.

Over temperature protection

 

Automatically recoverable under 65°C ambient temperature

The detailed information is listed in “GPR4830A rectifier specification”.

 
5.2 Installation of Rectifier Module
 
Handles on panel of rectifier module are equipped. When inserting rectifier module into the main cabinet, the operator shall clutch the handle with one hand while holding it with the other hand. Slowly push the module into its slot until the connection terminal on back of the module is inserted into corresponding socket of system bar in the main cabinet. Finally, finish the installation by firmly fixing the screw on the panel to the main cabinet. When removing module from the main cabinet, first screw off the bolt on panel then slowly remove the module from its slot while clutching the handle.
 
6. System Maintenance
 
(1) Failure: yellow LED on rectifier module flickers, communication fails;
Maintenance solution: check the communication network to see whether the internet connection is loose, internet interface is damaged, or network wire is damaged.
(2) Failure: yellow LED on rectifier lights on;
Maintenance solution: check whether the fan is blocked, load current exceeds the max. value; AC voltage is too low, then the auto rate decrease starts; over temperature pre-alarm starts; remote shut-down is started on PC software.
(3) Failure: Red LED on rectifier lights on;
Maintenance solution: check whether the voltage is too high/too low and over/under voltage protection is on; fan is blocked; ambient temperature is too high; load is short circuit or not.
If above mentioned parts are ok but the red LED is still on, then there is problem on the module, please return it to factory for repairing.
(4) Failure: Yellow, red, green LEDs on rectifier are all off;
Maintenance solution: firstly check whether AC input is available or not, if not, then check the electrical circuit; if yes, the module is in malfunction, please return the module to factory for repairing.
 
 

Contact Details
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Person: Ms. Fiona Liang

Tel: 86--13752765943

Send your inquiry directly to us (0 / 3000)