TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

 

We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom power system.

Sales & Support
Request A Quote - Email
Select Language
English
Portuguese
中文
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsOne Compartment Outdoor Telecom Cabinet

ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit

China ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit supplier

Large Image :  ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit

Product Details:

Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001:2008
Model Number: ET77100200

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Packaging Details: Wooden Case
Delivery Time: 15~20 Days
Payment Terms: T/T,L/C
Supply Ability: 80000 Sets Per Year
Contact Now
Detailed Product Description

ET9090170 Outdoor Telecom Cabinet 

1. Application Scope
 
The Outdoor Telecom Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.
 
2. Cabinet Introduction
2.1 Cabinet Material
 
The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF. The cabinet is assembled type.
 
2.2 Cabinet Structure
 
The cabinet is equipment cabinet, including 19” equipment installation rack, with air conditioner and heat exchanger integrated unit on cabinet door.
 
2.3 Cabinet Door and Lock
 
The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.
 
3. Features
 
3.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment. 
3.2 The cabinet cooling uses air conditioner and heat exchanger integrated unit .
3.3 Including -48VDC illumination lamp.
3.4 The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc. 
3.5 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable. 
3.6 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials. 
3.7 The cabinet uses assembled structure, easy for installation.
3.8 The cabinet includes 19” standard installation rack.
 
4. Technical Specs
 
(1) Applicable environment conditions:
Environment temperature:  -40°C ~ + 70°C
Environment humidity (RH):  ≤95% (at + 40°C)
Air pressure: 62kPa ~ 102kPa
(2) Material: good quality galvanized steel
(3) Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
(4) Cabinet load bearing: ≥600kg
(5) Ingress protection: IP55
(6) Flame retardance: comply with GB5169.7 test A
(7) Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2X104M /500V(DC).
(8) Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
(9) Mechanical strength: each surface can bear upright pressure>980N; after the door is open, its outer end can bear upright pressure >200N.
 
Dimension Diagram
 
Cabinet External Dimension (W×D×H): 770×1000×2000mm.
 
 
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated UnitET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated UnitET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
5. Sensors Installation 
 
5.1 LED lamp, smoke sensor and door sensor are installed at the top of the cabinet. 
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
5.2 Water sensor is installed at the bottom of the cabinet.
 
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
 
 
 
6. Wire Routing Design
 
Feeder cable and other external cables all use bottom wiring method.
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
 
 
7. Grounding Protection
 
(1) The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
(2) The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
(3) Protective earthing of other equipments inside the cabinet should be connected to the grounding bar. 
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
 
 
8. Theft Proof Design
8.1 Door lock theft proof design 
 
(1) Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
(2) Three point lock 
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
8.2 Connection and Fastening
(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2) Door hinges use inner hinge mode.
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
8.3 Appearance and Surface Treatment 
 
Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.
 
9. Cabinet Installation
 
9.1 Position of installation holes at cabinet base are as follows:
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
9.2Users prefabricate concrete base.
9.3 Pre-embed 4pcs M10×120 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1. Bolt exposed height is 40mm. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench. 
9.4 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts. 
 
10. PDU Principle Diagram
ET77100200 Outdoor Telecom Cabinet With Air Conditioner and Heat Exchanger Integrated Unit
 
10.1  PDU AC input voltage: 200 - 240VAC, DC input voltage: 45-56VDC.
10.2  AC MCB 63A/2P: Model: DZ47-63; Specs: 400VAC, GB10963.1, 3000A.
      AC MCB 16A/1P: Model: DZ47-63; Specs: 230/400VAC, GB10963.1, 3000A.
      DC MCB 16A/1P: Model: DZ47-63; Specs: 250VDC, GB10963.2, 3000A.
      Grade B SPD: Model: XLR-100; Specs: Uc: 385VAC; Imax:100KA; In: 60KA; Up<2.3KV. 
 
11. Air Conditioner and Heat Exchanger Integrated Unit
See the Annex 1  “KR06-150JSH/01 Manual”.
 
12. Environment Monitoring System
See the “SM2400 Manual” and “Sensors Specs”.
 
 
13. Packing, Transport and Storage
 
13.1 Packing
 
The cabinet packing is wooden case in compliance with GB3873-83, damp proof and shock proof. The outside of the packing is painted with damp proof sign, shock proof sign, direction sign, etc.
 
13.2 Transport
 
The cabinet can be transported by various transportation ways. During the transportation, the environment temperature should be -40°C~+70°C, the relative humidity should be ≤90%(at +30°C). There should be a awning to prevent the product from rain and sunshine. Loading, unloading and moving of the product should be carried according to the transportation signs painted on the packing.
 
13.3 Storage
 
In the warehouse, the acid gas, Alkaline gas or other harmful gas should comply with the environment protection requirement. Storage temperature: -5°C~45°C, relative humidity≤75%.
 
 