Product Details:
Payment & Shipping Terms:
|
External Size: | 800*800*2000MM | Protection Level: | IP65 |
---|---|---|---|
Type: | Switch Box | Operating Temperature: | -40°C ~ + 45°C |
Storage Temperature: | -25°C ~ + 55°C | Air Pressure: | 62kPa ~ 101kPa (similar To 0m ~ 5000m Altitude) |
Material: | Good Quality Galvanized Steel | Surface Treatment: | Degreasing |
Cabinet Load Bearing: | ≥600kg | Flame Retardance: | GB5169.7 Test A |
The Outdoor Telecom Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.
The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The
insulation material is 20mm PEF. The cabinet is assembled type.
The cabinet is equipment cabinet, including 19” equipment installation rack, with air conditioner on cabinet door.
The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.
3.1 The cabinet is dustproof, sun proof and rainproof, which is used in outdoor environment.
3.2 The cabinet cooling uses air conditioner.
3.3 Including -48VDC illumination lamp.
3.4 The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc.
3.5 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.
3.6 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
3.7 The cabinet includes 19” standard installation rack.
(1) Applicable environment conditions:
Operating temperature: -40°C ~ + 45°C
Storage temperature: -25°C ~ + 55°C
Transport temperature: -40°C ~ + 70°C
Relative humidity (RH): 5%~99%
Air pressure: 62kPa ~ 101kPa (similar to 0m ~ 5000m altitude)
(2) Material: good quality galvanized steel
(3) Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
(4) Cabinet load bearing: ≥600kg
(5) Ingress protection: IP65
(6) Flame retardance: comply with GB5169.7 test A
(7) Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
(8) Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
(9) Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.
See “TC06-150JFH/01 Manual”.
See the “Environment Monitoring System Manual”.
The cabinet packing is wooden case in compliance with GB3873-83, damp proof and shock proof. The outside of the packing is painted with damp proof sign, shock proof sign, direction sign, etc.
The cabinet can be transported by various transportation ways. During the transportation, the environment temperature should be -40°C~+70°C, the relative humidity should be ≤90%(at +30°C). There should be a awning to prevent the product from rain and sunshine. Loading, unloading and moving of the product should be carried according to the transportation signs painted on the packing.
In the warehouse, the acid gas, Alkaline gas or other harmful gas should comply with the environment protection requirement. Storage temperature: -5°C~45°C, relative humidity≤75%.