Product Details:
Payment & Shipping Terms:
|
Description
The cabinet is one compartment, double-wall cabinet. The cabinet cooling uses AC air conditioner and fans, to ensure the equipments operate normally at stable temperature range, so as to make the service life of the equipments much longer and their performance more stable.
Technical Parameters
Item |
Type |
Technical Parameter |
Structure |
Dimension |
External Dimension: H*W*D 1650*800*1000mm Internal Dimension: H*W*D 1350*740*950mm |
Layout |
1 compartment |
|
Equipment Installation Method |
19” rack |
|
Door |
With one front door and one back door, and special lock for outdoor cabinet (support padlock) |
|
Material |
Galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate |
|
Heat Insulation |
There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF. |
|
Structure |
Welded |
|
Ingress Protection |
IP55 |
|
Temperature Control |
Cooling |
AC220V air conditioner and DC48V fans |
Lightning Proof |
Grade B lightning proof |
Nominal: 60KA, Max.: 100KA |
Lighting |
LED lamp |
48V LED lamps (immovable), with protective circuit breaker |
Temperature |
Temperature |
Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C |
||
Transport Temperature: -50°C ~ +70°C |
||
Humidity |
Relative Humidity |
5% ~ 100% |
Pressure |
Air Pressure |
62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity |
Solar Radiation Intensity |
1120 ×(1±5%)W/m2 |
Accessories List
No. |
Item |
Quantity |
Unit |
Specs |
1 |
Outdoor Telecom Cabinet |
1 |
Set |
(1) External Dimension: H*W*D 1650*800*1000mm; Internal Dimension: H*W*D 1350*740*950mm. (2) 1 compartment; (3) With one front door and one back door, and special lock for outdoor cabinet (support padlock) ; (4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate; (5) Welded. |
2 |
Air Conditioner |
1 |
Set |
Cooling capacity: 1.5KW, AC220V, 50HZ |
3 |
110V to 220V Transformer |
1 |
Set |
110V to 220V transformer, 1000W |
4 |
Water Sensor |
1 |
PC |
|
5 |
Smoke Sensor |
1 |
PC |
|
6 |
Environment Monitoring Unit |
1 |
Set |
2U |
7 |
UPS |
1 |
Set |
Model: D3K |
8 |
Temperature and Humidity Sensor |
1 |
PC |
|
9 |
Power Distribution Unit |
1 |
Set |
Lightning proof: single phase, nominal 60KA, Max. 100KA; AC Input:: 63A/2P*1; AC Output: 20A/1P*2; Maintenance Socket: single phase, three holes *1 |
10 |
LED Lamps |
2 |
PC |
DC48V |
11 |
Auxiliary Direct Ventilation Fans |
2 |
PC |
12038 DC48V |
12 |
Lead Acid Battery |
4 |
SET |
12V 150AH |
13 |
Door Sensor |
4 |
PC |
Control LED lamps |
14 |
LED lamp Circuit Board |
2 |
PC |
|
15 |
PDU |
1 |
Set |
Remotely Manageable PDU, Model: NP-16R |
16 |
Package |
1 |
Set |
Wooden Case |
Lead Acid Battery Specs
Model |
Rated Voltage |
Capacity (AH) |
Weight |
Terminal Specs |
Dimension(mm) |
Internal Resistance |
Short Circuit Current |
Terminal Position |
(V) |
(Kg) |
(L*W*H) |
(mΩ@25°C) |
(A) |
||||
RA12-150 |
12 |
150 |
44.5 |
F5/F12 |
483*170* 240(240) |
4.3 |
2700 |
C |
UPS Specs
Techinical Parameters
Model |
D3K |
|
Rated Output Capacity |
3000VA/2400W |
|
AC Input |
Input Mode |
Single Phase Grouding |
Rated Voltage |
100/110/120Vac |
|
Rated Frequency |
50Hz |
|
Input Voltage Range |
80~ 145VAC±5 |
|
Input Frequency Range |
(45~55) ± 0.5Hz |
|
Bypass Voltage |
80VAC×(1± 5%) ~ 145VAC×(1± 5%) |
Battery Input |
Battery String Voltage |
96VDC; Optional (48V, 72V) |
Battery Number |
8; Optional (4,6) |
|
Backup Time (Half/Full) |
Half load ≥10 minutes, Full load ≥5 minutes (standard type) |
|
Power On Input Max. Impulse Current |
< 150% of Rated Current |
|
Battery Charge Time |
Charge to 90% within 5 hours (standard type) |
AC Output |
Output Mode |
Single Phase Grouding |
Output Voltage |
100/110/120Vac ± 3% (Inverting Output) |
|
Output Frequency |
50 ± 5Hz ( When the AC input is normal) 50Hz ± 1% ( When the AC input is abnormal) |
|
Dynamic Voltage Transient |
< 5% |
|
Dynamic Transient Recovery Time |
< 60ms |
|
Waveform |
Sine WaveTHD < 3% (linear load) Sine WaveTHD < 8% (nonlinear load) |
|
Output Power Factor |
0.8 |
|
Overload Capability |
130% load lasts for not less than 30s, recovery point is 90% load. |
|
Output Current Peak Factor |
3:1 |
|
Inverting to Bypass Time |
<4ms |
Communication and Monitoring Function |
RS232 ( can be turned to RS485), dry contact, intelligent socket (can expand multiple monitoring mode such as SNMP, mobile phone text massage etc.) |
Audio Noise |
< 55dB (1m) |
Weight (kg) |
28 |
Dimension (W*D*H mm) |
190*318*433 |
Cabinet Layout Diagram
Fans Cooling Diagram
Air Conditioner Cooling Diagram