![]() |
|
|
Product Details:
Payment & Shipping Terms:
|
Dear Vivek Kumar,: | -40°C ~ +55°C | Storage Temperature: | -50°C ~ + 70°C |
---|---|---|---|
Transport Temperature: | -50°C ~ +70°C | Door: | With One Front Door And One Back Door, Totally Two Doors |
Protection Level: | IP55 | Cooling: | 500W Air Conditioner |
1, Description Of Outdoor Network Cabinet
This Outdoor Network Enclosure is IP55 protected. It secures protection of electrical components from corrosive materials and dust. Our Network Cabinet guarantees high efficiency safety and reliability. Our Network Cabinet comes with different sizes and styles. We also do modification and customization according to your requirements.
2, Selling points and Feature Of Outdoor Network Enclosure
- Material: galvanized steel or as customer's requirements
- Cooling System: Air conditioner(Fans,or Heat exchange)
- Protection Level: IP55 ,Waterproof,dust proof.
- Sealed by import seal belt, waterproof design realize the efficient protection
- Machine Protection Solution: the cabinet is designed specifically to protect it from human damage, earthquake and other damages.
3, Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension |
External Dimension H*W*D 1200*900*900mm Internal Dimension H*W*D 900*800*800mm |
Layout | One compartment | |
Equipment Installation Method | 19” standard rack | |
Door | With one front door and one back door, totally two doors | |
Material | Galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. | |
Structure | Assembled | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | 500W Air Conditioner and fans |
Lighting | LED lamp | 48V LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
4, Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Telecom Cabinet | 1 | Set |
(1) External Dimension H*W*D 1200*900*900mm ; Internal Dimension H*W*D 900*800*800mm (2) One compartment; (3) With one front door and one back door, totally two doors; with special lock for outdoor cabinet (support padlock) (4) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
2 | Air Conditioner | 1 | Set | 600W Air Conditioner, AC220V power supply |
3 | 110V To 220V Transformer | 1 | Set | Used for air conditioner input |
4 | Fans | 2 | PC | DC48V |
5 | Power Distribution Unit | 1 | Set |
Grade B Lightning Proof AC Input: 63A/2P *1; AC Output: 16A/1P*4; DC Output: 16A/1P*4. Height: 4U |
6 | Embedded Telecom Power System (UPS) | 1 | Set |
DC48V, 60A, 3210W; Model: 1U-4860, Height: 1U. |
7 | Package | 1 | Set | Wooden Case |
5, Enclosure Cooling
One set Air conditioner and 2 pcs DC48V fans.
6, Cabinet Structure
(1) External Dimension H*W*D 1200*900*900mm ;
Internal Dimension H*W*D 900*800*800mm
(2) One compartment;
(3) With one front door and one back door, totally two doors
(4) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.
7, Cabinet Layout Diagram:
Installation and Electrical Wiring Instruction
8.1 Preparation Before Installation
(1) Prepare the tools in the following table “Installation And Maintenance Tools”.
(2) Check the air vents to ensure there’s no unnecessary items on the vents.
8.2 Installation And Maintenance Tools
Tools Name | Function |
Cross Screwdriver | Fix air conditioner. |
Small Slotted Screwdriver | Wire power supply port on the panel |
Wire Stripper | Wire stripping |
Wire Crimper | Crimp power supply for equipment |
Multimeter | Check the wiring to ensure it’s correctly connected and without short circuit. |
Clamp Meter | Test operating current of the air conditioner |
8.3 Installation Steps
Make sure the air conditioner is not connected with power.
Fix the air conditioner according to the Dimension Diagram.
Strip the insulation of the power supply wire, and crimp the terminal.
Connect the wires according to the Electrical Wring Diagram.
After finishing the wiring, use the multimeter to check if the electric circuit is normal. Then connect the air conditioner with power supply, and use clamp meter to test the operating current.
Note: Make sure to disconnect all the power supply to the air conditioner before installation. Choose proper wire diameter and test operating current according to the technical parameters of the air conditioner.
FAQ
Q1: Are you a manufacturer?
A: Yes, we are a experienced manufacturer with our own design and production lines.
Q2. Do you have any MOQ limit for outdoor cabinet ?
A: Low MOQ, 1pc for sample checking is available.
Q3: Can I get sample order?
A: Yes, we would like to get your sample order for testing our quality, the sample cost is paid by the customer.
Q4: Are you able to customize items with design or logo?
A: Yes, OEM & ODM is available.
Q5: How do you ship the goods and how long it will take?
A: We normally make shipment by sea or air which usually takes about 10- 50 days depend on the destination.
Q6: How long is the product warranty ?
A: We guarantee all our products 12 months warranty.