TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players

China TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players supplier
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players supplier TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players supplier TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players supplier

Large Image :  TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players

Product Details:

Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001:2008
Model Number: TC06-100ZEH/01(KT041)

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Packaging Details: Wooden Case
Delivery Time: 10~15 Days
Payment Terms: T/T
Supply Ability: 80000 Sets Per Year
Contact Now
Detailed Product Description

1000W DC48V Advertising Machine Air Conditioner
Model: TC06-100ZEH/01(KT041)
 
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players
 
1. Introduction
 
The TC06-100ZEH/01 air conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information. The product is widely applied in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
 
2. Features
 
(1) Strong adaptability
(2) High intelligence 
(3) High precision
(4) High reliability
(5) Low noise 
(6) Low energy consumption
(7) With 4 way switching value detection
(8) With 1 way room air conditioner control
(9) Wide input voltage range: 48VDC±15%  
(10) With dry contact alarm output 
 
 
3. System Principle Diagram
 
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players
 
 
Diagram 1: System Principle Diagram
 
4. Standard Compliance
 
                                            Table 1 Standard Compliance

Standard

Description

GB/T 17626.7-1998

Electromagnetic compatibility

GB4706.1

Safety of household appliance and electrical appliance with similar use.

GB4798.1

Environmental conditions existing in the application for electric and electronic products - storage

GB4798.2

Environmental conditions existing in the application for electric and electronic products - transportation

GB4798.3

Environmental conditions existing in the application for electric and electronic products - usage

 

 

 

 

 

 

 

 

 

 

 

 

 
5. Technical Parameters
 

Model No.

TC06-100ZEH/01

Environmental Performance

working environmental temperature

-20°C ~ 55°C

storage working temperature

-40°C ~ 70°C

working humidity

≤95%

Thermal Performance

rated cooling capacity

1100W(L35 L35)

1000W(L25 L35)

heating input power

Option

 

Electrical Performance

rated input current

6.0A(L35 L35)

5.8A(L25 L35)

rated input power

288W(L35 L35)

278W(L25 L35)

input voltage

DC48V

Reliability

MTBF

60000 hours

Noise

≤65dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players

6. Electrical Wiring Instruction
 
6.1 Electrical Wiring Diagram
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players
 
 
Wiring Ports:
 
0V -48V: power supply input (voltage input: 48VDC±15%)
F+  F- : direct ventilation output 
AL1 AL2: general alarm output
A+ B- SGND: RS485 communication interface
N: not connected pin
 
7. After mechanical installation and electrical installation are finished, check the installation items.
 
(1) Make sure the air conditioner is firmly installed.
(2) Check the electrical installation circuit, and ensure it doesn’t have short circuit.
(3) Check the air outlet, air inlet, internal fan and external fan of the air conditioner, and ensure they don’t have any odds and ends.
(4) Connect the air conditioner to power supply, and test the power supply (voltage input: 48VDC±15%), operating current 5.9A±4%.
 
8. System Control 
 
Terminology:
BTH: Temperature & Humidity of Box;
ETH: Temperature & Humidity of Engine Room;
BAC: Box Air Conditioning;
CAC: Cabinets Air Conditioning;
BACS: Box Air Conditioning Start Times;
BACR: Box Air Conditioning Run Time;
CACS: Cabinets Air Conditioning Start Times;
CACR: Cabinets Air Condintioning Run Time;
VP Temp.: Vent-pipe Temperature;
AC FSV: Air Conditioning Value of Current;
CPar: Parameter of Control;
BPar: Parameter of Base;
A/M: Automatic / Manual;
MaxTemp: Maximum Temperature;
MixTemp: Minimum Temperature.
 
8.1 Application
 
ET872 thermostatic battery cabinet controller is a type of universal intelligent controller. It is controlled by highly integrated STC single chip microcomputer. It can intelligently control operating and hydrogen exhaust of thermostatic cabinet air conditioner, and can control a telecom room air conditioner. It have the following functions: fault self diagnosis, power on self start, restart after unexpected failures caused by other reasons.
  
The controller features perfect performance, easy and fast installation and setting, which is widely used in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
 
8.2 Main Technical Parameters
 
a. 2×16 Chinese/English shift LCD display, user friendly; 
b. Simultaneously display temperature and humidity inside the box and communication room temperature;    
c. Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:4%;
d. Can store 180 days’ daily event record, 1 record every day;
    Daily highest temperature, lowest temperature, average temperature
    Daily event record;
e. Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
f. RS485 or RS232 communication,RTU-Modbus protocol, support remote detection and control;
g. Use PID control algorithm, intelligently adjust output power, optimize energy efficiency;  
h. Controllable air conditioner quantity: 2 sets. 1 set of air conditioner for communication room, and 1 set of air conditioner for thermostatic cabinet.
i. Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner);
j. Real-time control air conditioner on/off
k. Power supply: DC48V;
l. Power consumption:≤5W;
m. Working environment: -30°C~70°C; <90%RH;
n. Installation method: guide rail,hanging;
o. Dimension(L*W*H):150mm×190mm×45mm
 
8.3 Operating Instruction
 
ET872 uses user-friendly interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:
 
 
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players
 
8.3.1 Buttons
 
PgDn:page down button, confirm button.      
Press once and release the button, page down;
A long press on the button, enter or exit parameter status;
At operating status: can select five display interfaces;
At parameter status: revise, confirm and parameter page down button; a long press on the button to exit parameter status.
 
▲:increasing parameter revision. Page down button for event query.  
 
▼:decreasing parameter revision. Page up button for event query.
 
PgUp: page up button; the function is oppose to PgDn operation.
 
 
8.3.2 Indicators
 
When the air conditioner works normally, the Work indicator flashes at 2s frequency, showing it is working normally. When there is screen saver, the indicator can indicate the system is working normally.
 
When the system has alarm, the Alarm indicator will turn on, showing alarm occurs. 
 
8.3.3 Operating Interfaces 
 
The controller includes three working modes: operating mode, parameter mode, and query mode.
 
(1) Operating Mode:
 
The mode is normal working mode. There are five operating interfaces which can be selected. The five interfaces display different content. When they are not selected, the interfaces will automatically shift. Press the button “PgDn” to select next display interface; press the button “PgUp” to select the previous display interface.   
 
Interface 1: 
 
Line 1: temperature and humidity inside the thermostatic box (or area I);
Line 2: temperature and humidity inside communication room (or area II);
Diagram 4 is the first interface (main interface) of this mode.
 
Interface 2: 
 
Line 1: control status indication. Separated by the sign “/”, the former is box air conditioner status: “OFF” means compressor and heater both stop; “xx%” means compressor output percentage; “¤” means heater are working; “♂” means hydrogen exhaust or direct ventilation. The latter is cabinet air conditioner status: “Off” means stop; the first “*” means cabinet air conditioner control; the second “*” or “>” is actual status, means the air conditioner is at cooling status; If it display “>”, it means the air conditioner only blow air. 
 
Line 2: real time, manual/auto status. “Auto” means auto status, “Menu” means manual status.
 
At manual mode of this interface, press buttons “▲,▼” can manually increase or reduce control output of box air conditioner, and the control output of fan will increase or reduce synchronously.
 
Interface 3: 
 
Display real rotational speed of inner fan and outer fan.
 
At manual mode of this interface, press buttons “▲,▼” can manually turn on/off control output of cabinet air conditioner.
 
Interface 4: 
 
Display temperature of inner coil and outer coil.
 
At manual mode of this interface, press buttons “▲,▼” can manually turn on/off control output of hydrogen exhaust.
 
Interface 5: 
 
Circularly display current alarms;
When multiple alarms occur, it will display each alarm information circularly.
 
(2) Parameter Mode:
 
At operating status, long press on the button ”PgDn” for around 3 seconds, or press the button ”PgUp” at interface 1, to enter parameter mode.The first entered interface is the main menu interface, see the following diagram.
                TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players
 
Press the button “▲”, “▼” to choose corresponding parameter group; Press ”PgDn” to enter corresponding parameter group; Press ”PgUp” to return to operating mode. The parameters selection includes:
 
(a) Observation Parameter 
(b) Control Parameter Revision  
(c) Basic Parameter Revision 
(d) Manual/Auto Selection 
(e) Event Query 
(f) Return To Operating Mode 
 
(a) Observation Parameter Group (Apar):
 
Enter the interface to check some parameters which can’t be checked at operating mode, see “8.3.4 Parameter Instruction”. 
 
At parameter mode: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
 
(b) Control Parameter Group (CPar):
 
Enter the interface to observe or revise the parameters which can be revised, see “8.3.4 Parameter Instruction”. 
 
At parameter mode: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
 
(c) Basic Parameter Group (BPar): 
 
Enter the interface to observe or revise the parameters which can be revised, see “8.3.4 Parameter Instruction”. 
 
At parameter mode: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
 
(d) Manual Operation Parameter Group (A/M):
 
Enter the interface to select “Cool”, “Heater”, “Air”, “ToAuto” to conduct manual start and stop operation.
 
(e) Event Query (Query):
 
Enter query mode
 
8.4 Wiring Diagram
 
 
TC06-100ZEH/01(KT041), 1000W DC48V Compressor Air Conditioner For Advertising Players

Contact Details
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Person: Ms. Fiona Liang

Tel: 86--13752765943

Send your inquiry directly to us (0 / 3000)