STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

China STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function supplier

Large Image :  STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

Product Details:

Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001:2008
Model Number: STC-CPL48120ER

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Packaging Details: Wooden Case
Delivery Time: 15~20 Days
Payment Terms: T/T,L/C
Supply Ability: 10000 Sets
Detailed Product Description

Power System of High Performance and High Reliability
 STC-CPL48120ER Embedded Power System
 Input: 90~280Vac; Output:-43.2~-57.6Vdc;Power: 6420W
Application
 
■   Program controlled exchanger
■   Access network
■   Transmission equipment
■   Mobile communication
■   Satellite communication ground station
■   Microwave communication
 
Features   
   
■    Total capacity: -53.5Vdc/(10~120)A
■    Standard 19in./3U,easy to be embedded to all kinds of telecom equipment and cabinets
■    Adoption of active power factor compensation 
■    Normal operating range of AC input voltage:90~280Vac
■    Operating temperature range: -20℃~+65℃
■    Adoption of softswitch tech with efficiency of 91% or above
■    Perfect battery management, LVLD&BLVD
■    Hot pluggable 
■    Excellent lightning proof design applicable to areas with frequent thunderstorms
■    Input over/under voltage protection
■    Output over voltage/current protection
■    Output short circuit protection
■    LED indicators on front panel
■    Compliant to UL 60950, CSAC22.2 60950-00,VDE0805 IEC60950
■    CE mark meets directives of 73/23/EEC and 93/68/EEC
 

Basing on years development and operating experience, the embedded power system is a newly-designed product, which is of high performance and high reliability. The system size is standard 19in. /3U, can be embedded into all kinds of telecom equipments and cabinets. It is also of wide range of input voltage and operating temperature, high efficiency and the hot plug makes it is easy for maintenance. 

 

1.System operating principle 

 
AC power is first input AC-INPUT circuit breaker and then fed into the rectifier module after the EMI filtering. AC-INPUT functions as over load and short circuit protection to AC power. Load LVD contactors KM1, KM2 are connected in series with the LOAD1 and LOAD2. The user’s battery is connected to the DC output through BAT circuit breaker and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.
 
Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage drops to below -47V (settable), the monitoring module will report the DC under-voltage alarm signal. When the voltage drops to -45.0V (settable), the monitoring module will make KM1 cut off LOAD1 while retaining LOAD2.The power system just powers to LOAD2. When the voltage drops below -43.0V (settable), the KM2 acts to cut off LOAD2 output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values, users can reset).
 
Except for battery over-discharge protection, battery or load over-temperature protection function is prohibitive under default condition, users can send command to activate or inactivate according to the demand.
 
2. System configuration
2.1  4 Nos rectifier modules
       Options: CPL4810RM, CPL4815RM, CPL4820RM, CPL4830RM;
 
2.2  1 Nos monitoring module
        Options: CPL48D(RS485, LCD), CPL48DI (RS485, TCP/IP, LCD), CPL48I(RS485);
 
2.3  1 Nos surge protection module (20KA)
 
2.4  Distribution part .
AC Distribution: single phase, 3 lines, double-pole AC breaker 60A of general power supply;
DC Distribution: battery fuse 80A×1;
LVBD: 100A×1;
LVLD: 200A×1

 

STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

  1. AC input socket-3 core 2. Fixing hole

                                                      3. MCB                                4. Surge protection module

                                                      5. Rectifier module           6. Monitoring module

                                                      7. Load output connectors

3.Line diagram:

STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

 

4.Properties 

(The specifications are for system configured with 2 Nos rectifiers of 30A if not specified.)

Input

Parameter

Min.

Typical

Max.

Unit

Remark

Input voltage range

90

220

280

Vac

 

Input frequency

45

50

65

Hz

 

Input current

 

 

37.3

A

 

Power factor

0.98

   

 

 

 

 

Output

Parameter

Min.

Typical

Max.

Unit

Remark

Output voltage range

-43.2

-53.5

-57.6

Vdc

 

Output current range

4Nos rectifiers of 30A

0

 

120

A

175~280VAC

0

 

60

A

150~175VAC

0

 

45

A

90~150VAC

4Nos rectifiers of 20A

0

 

80

A

175~280VAC

0

 

45

A

90~175VAC

4Nos rectifiers of 15A

0

 

60

A

175~280VAC

0

 

37.5

A

90~175VAC

4Nos rectifiers of 10A

0

 

40

A

175~280VAC

0

 

20

A

90~175VAC

Regulation

 

 

±1

%

 

Load regulation

 

 

±1

%

 

Line regulation

 

 

±1

%

 

Weighted psophometric noise

 

 

2

mv

 

Wide frequency noise voltage

 

 

 

 

50

20

mv

mv

3.4KHz~150KHz

150KHz~30MHz

Ripple(Vp-p)

 

 

200

mv

Rated input/ output, add 0.1uFfilm capacitor and10uF high frequency electrolyte capacitor, oscilloscope band width is20MHz

Current sharing

 

 

±5

%

 

Output power

 

 

6420

W

4Nos rectifiers of 30A

 

 

4280

W

4Nos rectifiers of 20A

 

 

3210

W

4Nos rectifiers of 15A

 

 

2140

W

4Nos rectifiers of 10A

Output efficiency

91

 

 

%

220Vac input

83

 

 

%

110Vac input

 

 

Protection

 

 

Parameter

Unit

Min.

Typical

Max.

Recovery Property

 

Input over-voltage

Vdc

285

305

 

Auto recovery

 

Input over-voltage recovery set point

Vdc

280

 

 

Hysteresis not less than 5V

 

Input under-voltage

Vdc

 

 

85

Auto recovery

 

Input under-voltage recovery set point

Vdc

 

 

90

Hysteresis not less than 5V

 

Output over-voltage protection set point

V

58.5

59

61.5

Lock up

 

Output current limiting

A

96

99

102

Auto recovery

 

Short circuit

A

Long-term short circuit permissible; Hiccup when short circuit detected

 

Thermal protection

Auto recoverable under ambient temperature of 60℃.

 

Fan failure

 

When one fan fails, the module runs with automatic derating and reports alarm till the module high temp protection cuts off the output. When both fans fail, the module cuts off output after reporting alarm.

 

 

Ambient

Parameters

Min

Typical

Max

Unit

Remark

Operating temp.

-25

 

55

°C

 

Extended operating temp.

55

 

75

°C

Operation with derating

Storage temp.

-45

 

85

°C

 

Humidity

5

 

95

%

Relative humidity, non-condensing

Altitude

-60

-200

 

4000

13000

m

ft

For operation above 2500m (5000 ft.), the maximum operation temperature is derated by 2°C. per 305m (1000 ft.)

Shock and vibration

operation

test standard

drop and tumble

 

 

 

 

 

IEC 68-2

IEC 721-3-2

IEC 68-2-31

Earthquake rating

4

 

 

Zone

 

Noise

 

45

 

dB

Relative to fan speed, load and ambient temperature

Harmonic emission

EN/IEC61000-3-2

Radiated emission

EN55022 - Class B

Conducted emission

EN55022 - Class B 

ESD

EN/IEC 61000-4-2 Level 3 (Contact Discharge 6 kV, Air Discharge 8 kV).

Radiated immunity

EN/IEC 61000-4-3 Level 3 (10 V/m).

Conducted immunity

EN/IEC 61000-4-6 Level 3 (10Vrms).

EFT/B

EN/IEC 61000-4-4 Level 3 (2 kV, 5 kHz Repeat)

Lightning surge

 

Common mode 4kV, differential mode 2kV. 

AC input should bear lightning strike impact current waveform of 8/20us, ±5 times for impacts of 5KA

Isolation  properties

input-chassis

input - output

output - chassis

 

1500

3000

500

 

 

 

Vac Vac Vdc

 

 

 

 

Leakage current

 

 

3.5mA

 

264Vac Input

Insulation resistance

10MΩ

 

 

 

Tested at 500Vdc

 

 

Mechanical spec.

Length (in./mm)

19/482.6

Width (in./mm)

10/255

Height (in./mm)

5.14/130.5

Weight (kg)

≤11

5.Dimensional diagram

STC-CPL48120ER,Rectifier,120A/6420W,Modular Rectifier System,Battery Charging Function

 

Contact Details
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Person: Ms. Fiona Liang

Tel: 86--13752765943

Send your inquiry directly to us (0 / 3000)