GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac

China GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier
GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac supplier

Large Image :  GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac

Product Details:

Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001:2008
Model Number: GPEM1500-A

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Packaging Details: Wooden Case
Delivery Time: 15~20 Days
Payment Terms: T/T,L/C
Supply Ability: 30000 Sets Per Year
Contact Now
Detailed Product Description

 

  Power Supply of high reliability
GPEM1500-A Multi Power Supply System
Input: 90~280Vac; Output1: BAT,Output2:-48Vdc,Output3: 220Vac 
                               or: Input: -43.2~-57.6Vdc; Output3:220Vac

 

 
Application 
Integration access 
Indoor distribution and extension system
Mobile station and extension coverage system
WLAN 
Satellite communication ground station and microwave communication station
Weak current distribution room
Other AC/DC uninterruptible power system
 
Main features
Two outputs:-48Vdc,220Vac
Two inputs:-48Vdc,220Vac
Adoption of active power factor compensation technology, power factor >0.99
Wide operating range of AC input voltage:90~280Vac
Wide operating temperature range:-5℃~+55℃
Switch technology conducted,
Perfect battery management prolongs battery lifetime: charge /discharge management, battery temperature compensation, low-voltage protection.
Hot -swappable
Input over/under voltage protection
Output over-voltage protection, output over-current protection, output short-circuit protection
Embedded/wall mounted
RS485,RS232 communication interface
 
1. System Information 
1.1 GPEM1500-A System configuration
 
GPEM1500-A consists of distribution unit, rectifier module, conversion module, monitoring module. The configuration is optional, as table below: 
 

Configuration

Rectifier module

Monitoring module

Distribution

Remark

Standard

GPR4830A1 

 

DC Output:30A×1route(load)

Battery Output:30A×1route(battery)

For details, please refer to the specifications of modules

Standard

GPDA1000VA-G

220VACOutput:5A×1route (load)

 
1.2 GPEM1500-A Operating principle
 
GPEM1500-A consists of two modules: rectifier module (GPR4830A1) and conversion module (GPDA1000VA-G), system configuration is as below: 
 
System Configuration 
GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac
 
Two operating methods:
 
1. AC input:Startup rectifier module after AC powered-on, outputs -48Vdc,at the same time charge the battery and power the conversion module, conversion module outputs 220Vaac.
Under normal conditions, the parameters of rectifier module and distribution unit are all under controll of the monitoring module, operating according to the preset parameters or user’s commands. If AC mains fault, the battery will power to the system, and continue outputing - 48 VDC and 220 vac, with the discharge of the battery, the voltage of the battery starts to descend, when the voltage is under 43.2 V + / - 0.5 V, the monitoring module send battery under-voltage signal and close the load output directly, then the power system will stop working. When external AC mains recovers, the system will normally work again. (all above monitoring data are system default values and can be reset by user)
2. -48V input:No AC current or no AC be connected, access external power -48V to -48V load port, 
startup monitoring and conversion module, 220Vac output. 
 
Temperature compensation function is on by default, which can be activated or forbiddened by user’s command if necessary. Operation temperature ≥55℃, the power output of the power supply will be linearly reduced (@65℃,output power will be 1300W).
 

1.3 GPEM1500-A Specification

 

Input

Parameter

Min.

Typ.

Max.

Unit

Remark

Rectifier module

Input voltage range

90

220

280

Vac

Nominal operating voltage range: 100V-240V

Input frequency

45

50

65

Hz

 

Startup inrush current

 

 

50

A

25°C cold start,280Vac input,full-load

Power factor

0.99

 

 

 

220Vac input,output full-load

Conversion module

Input voltage range

43

 

58

Vdc

 

Startup inrush current

 

 

45

A

25°C cold start,< 150% of rated current

 

Output

Parameter

Min.

Typ.

Max.

Unit

Remark

Rectifier module voltage adjustable range

-43.2

-54

-57.6

Vdc

Default output 54V(adjustable by monitor)

Conversion module output voltage range

 

220

350

Vac

Default output220Vac

Rectifier module current range

0

 

30

A

176~280Vac input

Conversion module current range

0

 

4.28

A

43~58Vdc input

Ripple (Vp-p)

 

 

200

mV

Rated input and load,

Apply a 0.1uF ceramic capacitor and 10uF electrolyte capacitor to output,

oscilloscope bandwidth of 20MHz.

Stabilized voltage precision

 

 

±2

%

 

Load regulation

 

 

±2

%

 

Voltage regulation

 

 

±1

%

 

Rectifier module output power

 

 

1600

W

176-280Vac input

 

 

800

W

90-175Vac input

Conversion module output power

 

 

800

W

Conversion module output power

Bypass conversion duration

Duration for conversion to AC output≤20ms;

Duration for AC to conversion output≤10ms

 

AC bypass function

Bypass outputs when AC is normal,

Conversion outputs when AC is abnormal.

 

Insulation rating

parameter

Standard

Remark

Insulating strength(AC input)

Input-Output:3500Vdc/10mA//1min

No flashover or breakdown.

Remove discharge tube/surge protection device before testing, no rectifier module or monitoring module.

Output with 2 routes low-voltage terminal, high-voltage with AC bypass function, not to be tested.

Input-enclosure:3500Vdc/10mA//1min

Output-enclosure:750Vdc/10mA//1min

Insulating strength(DC input)

Input-Output:750Vdc/10mA//1min

Input-enclosure:750Vdc/10mA//1min

Output-enclosure:750Vdc/10mA//1min

Leakage current

≤3.5mA

280Vac input,output full-load

Insulation resistance

@ Normal atmosphere, relative humidity of 90%, Test voltage of DC 500V,the insulation resistance of input-output, input-ground, output-ground shall not be less than 10MΩ. Output with 2 routes low-voltage terminal, high-voltage with AC bypass function, not to be tested.

 

Environment

Parameter

Min.

Typ.

Max.

Unit

Remark

Operation temperature range

-5

25

+55

°C

 

Storage temperature

-40

 

+70

°C

 

Relative humidity

5

 

95

%

Long-term operating, no condensing

Atmosphere pressure

70

 

106

KPa

 

Altitude

0

 

3000

m

 

Cooling

Forced cooling, front-in & rear-out; the fan locates in front panel, with temperature controlled speed.

Water & dust proofing level

The power supply shall work properly under the following condition:

density of dust diameter above 55µm≤3*104 granule/m3.

The dust granule is non-conductive, non-electromagnetic, non-corrosive, without water-proof function.

 

Mechanical specification

Dimension

As figure below

Weight (overall)

≤6.3Kg(with module)

         ≤3.3Kg(without module,plug-in frame)

 

GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac

2. Installation

GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac

3. Electrical connection

3.1 Electrical connection
 
Electric connection between chassis and external parts is through system interface board.
As shown in figure below: 
GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac
 
4. Instruction of Monitoring Module of GPEM1500-A 
 
Monitoring module equipped with powerful detecting and controlling functions, which enables it to do real time detection to the power supply and control upon rectifier module according to detected data, for the purpose of meeting maintenance and management requirements of the battery groups and ensure reliable operating of the whole power system. It can receive queries, settings and control from the host through RS485 and report detected status and mechanical data to the host for the convenience of centralized management.
 
4.1 Feature
 
1. Equipped with RS485, through which the host can conduct query, setup, control and telemetering, remote control and remote signaling for the convenience of centralized management;
2. To manage the battery power down, battery charge/discharge, battery temperature detection, battery temperature compensation;
3. 3 dry contacts output;
4. LED indicator is located on the front panel and have alarm function. 
 
4.2 Function of monitoring module
 
The user interface of monitor module, rectifier module, conversion module, whole system and remote configuration via PC software are described in the block diagram. The power system communicates with the host via RS485, and it is point to multipoint communication, that’s one supervisory PC monitors several power systems.
 
GPEM1500-A,Multi Power Supply System, Two Inputs:-48Vdc, 220Vac, Two Outputs:-48Vdc,220Vac
 
Remote Monitoring of the Host
 
The monitoring module provides the host with RS485 Ports, through this port the host can remotely monitor the system and achieve remote massage/sense/control. RS485 networking is applicable from a distance within 1.2KM and RS232 for field communication. Main functions of monitor:
(1) Send real time analog data from the monitoring module to the host;
(2) Send real time digital data from the monitoring module to the host;
(3) Receive orders of the host including setting system parameters and start-up/shutdown of modules;
(4) Receive control commands from the host;
(5) Send alarm status the host.
All operations of reading, setting and controlling shall be conducted by the host. The monitoring module shall not report information without specific orders of the host.     
 
Signal Table
 

Data

Signal

Remark

Analog data

Rectifier module output current,bus bar voltage,battery current,load current,battery temperature

The monitoring module sends parameters and alarm to the host.

Digital data & alarms

module failure, DC under/over voltage, Primary power down, module start-up/shutdown, battery equalizing/float charge, battery over current

Parameters setup

Equalizing charge voltage, float charge voltage, DC output over- voltage alarm point, battery under-voltage alarm point, battery power down alarm point, battery capacity, Temperature compensation coefficient, Coefficient of equalized charging to floating charging, Coefficient of floating charging to equalized charging

The host sets the parameters and orders to the monitoring module.

Controlling orders

rectifier module start / shutdown, conversion module start / shutdown temperature compensation on/off

 
Rectifier Management by Monitoring Module
The monitoring module sends controlling orders to or receives parameter from the rectifier module through RS485.
(1) Regulate the output voltage: The monitor regulate equalizing/float charge   through background software and works out system output voltage based on status of system equalizing/float charge;
(2) Control start-up/shutdown of rectifier module;
(3) Check the output voltage, current, fan rotation and module failure alarm of rectifier module to ensure the normal operation.
 
Conversion Management by Monitoring Module
The monitoring module sends controlling orders to or receives parameter from the conversion module through RS485.
(1) Control start-up/shutdown of conversion module;
(2) Check the output voltage, current, fan rotation and module failure alarm of conversion module to ensure the normal operation. 
 
Battery Management
 
                                                                  Battery Management
 

Type

Description

Battery rectifying

The system background outputs alarm when the output voltage is under preset battery rectifying.

Battery power down

Under situation of battery discharge, when the voltage is below preset battery shutdown voltage, the battery DC relay will break off and shutdown all loads, cut off the connection between battery and system. The system will not work until the re-power on.

Battery configure

1. Fixed current charging: when the configuration is the 20-50Ah battery, the charge coefficient will be set to 5A; when the configuration is the 50-100Ah battery, the charge coefficient will be set to 10A. Specific settings such as the electrical connection diagram shown in the port 5 (temperature compensation port and the battery charging coefficient adjustment port), to adjust the dial code and set to the corresponding 5A/10A. (system default settings)

2. Adjustable current charging: through the background monitoring software to open the adjustable charge current switch and set the value of the charge current. (optional)

Battery equalizing/float charge management

When the battery charge current is high than pre-set upper value, the system will conduct equalizing charge of constant current (CC). If the CC equalizing charge reaches equalizing charge voltage, the system will act equalizing charge of constant voltage (CV). The system will float charge when the CV equalizing charge current is below current of equalizing charge shift to float charge. Under situation of float charge current more than current of float charge shift to equalizing charge, and the duration of system equalizing/float charge reaches preset time, the system will automatically  equalize charge. The system will automatically shift to float charge if CV equalizing charge duration exceeds preset value and the manual equalized charge will change over to equalizing charge.

Temperature compensation

Under situation of temperature compensation on, when the battery temperature is above 25℃, the system acts temperature compensation and if the battery temperature is below 25℃, the system acts minus compensation. The compensation value (equals to temperature*coefficient) shall not be greater than 2V.

 
Battery power down: if the mains fails, then the system power supply will be changed from the battery, with the discharge of the battery and the battery terminal voltage begin to decline, when the battery voltage is below the pre-set under-voltage point of battery voltage, monitoring module will report DC under-voltage alarm signal; when the battery voltage drops to battery power down voltage (adjustable), the monitoring module will control relay to close all the loads, and then the power system will stop working. When the mains recovers, the system will normally work again (the user can reset the parameters).
 
3 Dry contact output
 
  The dry contact output can be set, see table below:
 
                                                  Table: Dry contact description
 

Name

Type

Output state

Contact 1

    General alarm

Break off when alarm

switch on when normal

Contact 2

rectifier module alarm

Break off when alarm

switch on when normal

Contact 3

conversion module alarm

Break off when alarm

switch on when normal

 

 

Contact Details
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Person: Ms. Fiona Liang

Tel: 86--13752765943

Send your inquiry directly to us (0 / 3000)