TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

 

We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom power system.

Sales & Support
Request A Quote - Email
Select Language
English
Portuguese
中文
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsEnvironment Monitoring System

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

Certification
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Good quality Two Compartments Outdoor Telecom Cabinet for sales
Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

I'm Online Chat Now

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

China Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet supplier
Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet supplier Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet supplier Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet supplier

Large Image :  Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

Product Details:

Place of Origin: CHINA
Brand Name: ESTEL
Model Number: SM2200

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Packaging Details: wooden case
Delivery Time: 20 days
Payment Terms: T/T, L/C
Supply Ability: 10000 sets per month
Contact Now
Detailed Product Description

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

1. General Description

 

1.1  Control Board 

 

Diagram 1.1 shows the control board of the environment monitoring unit. It includes one 2*16 LCD screen, four operating buttons, four working indicator lights, and one power supply switch.

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

                                                                                      Diagram 1.1  Control Board 

(1) Power Switch: turn on or turn off power. 

 

(2) LCD Display Screen:

 

It shows different contents under the following three status. 

 

Operating Mode: the first line shows indoor temperature and humidity; the second line shows the real-time clock, among which the first letter “A” stand for automatic output, ”M” stand for manual output. One can directly revise DOx register to amend the output status.  

 

Menu Mode: can select eleven menu items in sequence.

 

Parameter Mode: shows parameter name and parameter value. For detail, please check the NO. 3 content. 

 

(3) Four buttons:

 

PgDn: 

At operating status: press once and release the button, enter menu operation interface;

At Menu selection interface: press once to enter the selected parameter group;

At parameter status: revise, confirm and parameter page down button; a long press on the button to exit parameters and to menu interface;

At query status: select the former day’s daily record, a long press on the button to exit query and to menu interface;

 

▲:increasing parameter revision. Page down button for event query.  

 

▼:decreasing parameter revision. Page up button for event query.

 

PgUp: 

At parameter status: page up button; the function is oppose to PgDn operation;

At menu selection interface: press once to exit parameter status and come to operating status;

At query status: select the latter day’s daily record; at current daily record, press the button to exit query.

 

(4) Four Status Lamps:

 

PWR : power indicator; when it is bright, it shows being connected with DC48V;

Work : when the system is working, it flashes at 1HZ frequency;

TEC : when this lamp is bright, it shows the TEC air conditioner is working(cooling or heating);

Alarm : system alarm occur. 

 

 

1.2  Wiring Ports

 

The following diagram shows the ports from left to right.

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

JD16: utility power detection input, DI13; 

JD15: universal analog input port 2;

  1, 4 - 12V; 3, 6 - 0V; 2 - AI3; 5 - AI4;

JD14: universal analog input port 1;

  1, 4 - 12V; 3, 6 - 0V; 2 - AI1; 5 - AI2;

JD13: universal digital input port 3; 

  1 - 12V; 6 - 0V; 2 - DI9; 3 - DI10; 4 - DI11; 5 - DI12;

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

JD12: universal digital input port 2; 

 

  1 - 12V; 6 - 0V; 2 - DI5; 3 - DI6; 4 - DI7; 5 - DI8;

JD11: universal digital input port 1; 

  1 - 12V; 6 - 0V; 2 - DI1; 3 - DI2; 4 - DI3; 5 - DI4;

Note: (1) Except DI13, all other universal DI can be redefined;  

          (2) Factory default: DI1 - door sensor; DI2 - smoke sensor; DI3 - water sensor;

JD10: temperature and humidity sensor 1 input port; 

  1 - 5V; 2 -Temp1; 3 - Hum1; 4 - 0V;

JD9: temperature and humidity sensor 2 input port; 

  1 - 5V; 2 - Temp2; 3 - Hum2; 4 - 0V;

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

JD8: communication port; 

 1 - SGND; 2 - B-(RS485)/TXD(RS232); 3 - A+(RS485)/RXD(RS232);

JD7: universal digital output port 4; 

 6, 5 - DO12; 4, 3 - DO11; 2, 1 - DO10;

JD6: universal digital output port 3; 

 6, 5 - DO9; 4, 3 - DO8; 2, 1 - DO7;

JD5: universal digital output port 2; 

 6, 5 - DO6; 4, 3 - DO5; 2, 1 - DO4;

Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

JD4: universal digital output port 1; 

 6, 5 - DO3; 4, 3 - DO2; 2, 1 - DO1; 

Note: (3) All the digital output DO can be redefined;

  (4) Factory default: 

  DO1 - door sensor; DO2 - smoke sensor;

  DO3 - water sensor;DO4 - utility power;

  DO5 - temperature 1 (battery compartment) alarm;

  DO7 - temperature 2 (equipment compartment) alarm;

  DO12 - system general alarm.

JD3: TEC air conditioner control output; when cooling, 1 anode, 2 cathode; when heating, 1 cathode, 2 anode; 

JD2: fan control output; 1 - cathode; 2 - anode;

JD1: DC48V power supply input; 1 - 0V; 2 - 48V;

 

1.3 Universal Analog Input 

 

Four way universal analog can be connected with 0~5V, 1~5V, 4~20MA signal; when connected with 4~20MA current signal, corresponding jumper (JP4 ~ JP7) should be with short circuit.

 

2. Technical Parameters

 

(1) Analog Input: eight way; four ways specially for temperature and humidity measurement, the other four ways for universal AI, 0 ~ 5V, 1 ~ 5V, 4 ~ 20MA universal input;

(2) Digital Input: thirteen ways; one way specially for utility power detection (220VAC input), the other twelve ways for universal DI input, function redefinable;

(3) Digital Output: fourteen ways; two ways specially for TEC air conditioner and fan control, the other twelve ways for universal DO output, function redefinable;

(4) Temperature Measurement Range: - 50°C ~ 85°C, accuracy 0.1 °C ; humidity measurement accuracy ±4%;

(5) Universal Analog AD Conversion Resolution: 10 bit;

(6) Three Control Modes for DO Output: manual output, SU remote control, automatic control;

(7) Intelligently control TEC air conditioner cooling / heating;

(8) Daily Record Storage And Query Function: recent 180 days’ daily records for query, including every day’s highest, lowest, average temperature, TEC air conditioner start times, operating time length, daily alarm event etc;

(9) RS232 or RS485 communication interface;

(10) Working Voltage Range: 36VDC ~ 72VDC;

(11) Working Temperature Range: -20°C ~ 80°C;

(12) Power Consumption: <10W

(13) MBTF: >50000 hours

 

3. Operation and Parameters

 

Note: please don’t change the settings of parameter group 4, 5, 6, 7, otherwise it may cause channel function failure. Generally they are already set by the factory before delivery.

 

3.1 Start  

 

When the Monitoring Unit is connected to power, the system self checking begins. After the checking, it will display “Success” (means normal) or “Failure”.

 

3.2 Enter and Exit Parameter Menu

 

Under the operating mode, press the button “PgDn”, the system will enter the menu mode. Diagram 3.1 shows the menu content.

                                                       Environment Monitoring System, with Digital Input and Analog Input, for Telecom Cabinet

 

Under this mode, through the buttons “▲” ”▼”, one can choose the following menu items in sequence: 

0:  AI  Look      // Analog input channel value query

1:  DI  Look      // Digital input channel status query

2:  DO  Look     // Digital output channel status query

3:  Event  Query  // Daily record events query

4:  AI  Define     // Analog input channel function definition

5:  DI  Define     // Digital input channel function definition

6:  DO  Define    // Digital output channel function definition

7:  ZF  Cal.       // Analog channel Zero amplitude adjustment

8:  CPar Update   // System control parameters revision

9:  Time Update   // Time parameters revision

10:  Return        // Return

 

After choose any menu item, press “PgDn” to enter the corresponding parameter group.

Under this mode, one can directly exit menu mode by pressing the button “PgUp”. 

 

 

 

 

 

 

 

 

 

 

Contact Details
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Person: Ms. Fiona Liang

Tel: 86--13752765943

Send your inquiry directly to us (0 / 3000)